STRUCTURED CABLING
SERVICES

Structured Cabling Lynnfield MA - Voice & Data

Allstate Electric Co., Inc. provides structured cabling voice and data networking services to businesses in Lynnfield, MA. Our structured cabling services include: network design and installation of all necessary jacks, cabling, and wiring, including Cat 5, Cat 6, fiberoptic, and coaxial cabling to provide consistent, reliable connectivity to your carrier's network.

  • VOIP Cabling & Installation Services Lynnfield, MA
  • Networking Cabling & Installation Services Lynnfield, MA
  • Structured Cabling Lynnfield, MA
  • Cat 5 Cabling Lynnfield, MA
  • Cat 5E Cabling Lynnfield, MA
  • CAT 6 Cabling Lynnfield, MA
  • Voice & Data Cabling Lynnfield, MA
  • Fibreoptic Cabling Lynnfield, MA

A structured cabling system is an integral piece of any well designed network. We are a "one stop shop" for all your organization structured cabling network infrastructure needs. Allstate Electric Co., Inc. designs, installs and builds flexible structured cabling infrastructures in businesses throughout Massachusetts.

Many times the decision of finding a cable contractor is left to the General Contractor and many times the General Contractor chooses to let the electrician pull all the wire. The electrician may not have the experience to provide your business with the best voice and data cabling solution. At Allstate Electric Co., Inc. we understand the intricacies of even the most complex networks. We will help you evaluate, design and install the optimum integrated system for your company.

To learn more about our voice and data cabling services contact
Allstate Electric Co., Inc. located in Woburn, MA 781-932-6600.

Click here to complete our online contact form.

 

Structured Cabling Lynnfield MA, Structured Cabling Systems Lynnfield MA, Structured Cabling Companies Lynnfield MA, Network Cabling Lynnfield MA, Voice And Data Cabling Lynnfield MA, Data Cable Installation Lynnfield MA, Network Installation Lynnfield MA, Fibre Optics Lynnfield MA, Fiberoptic Lynnfield MA, Fiberoptics Lynnfield MA, Cabling Companies Lynnfield MA, Cabling Company Lynnfield MA, Data Cabling Companies Lynnfield MA, Data Cabling Company Lynnfield MA, Network Cabling Companies Lynnfield MA, Network Cabling Company Lynnfield MA

What is Structured Cabling Wikipedia®

Structured cabling is building or campus telecommunications cabling infrastructure that consists of a number of standardized smaller elements (hence structured) called subsystems.

Structured cabling falls into six subsystems:

  • Entrance Facilities is the point where the telephone company network ends and connects with the on-premises wiring at the customer premises.
  • Equipment Rooms house equipment and wiring consolidation points that serve the users inside the building or campus.
  • Backbone Cabling connects between the equipment/telecommunications rooms, so named because the rooms are typically on different floors.
  • Horizontal Cabling wiring can be IW (inside wiring) or Plenum Cabling and connects telecommunications rooms to individual outlets or work areas on the floor, usually through the wireways, conduits or ceiling spaces of each floor.
  • Telecommunications Rooms or Telecommunications Enclosure connects between the backbone cabling and horizontal cabling.
  • Work-Area Components connect end-user equipment to outlets of the horizontal cabling system.

Structured cabling design and installation is governed by a set of standards that specify wiring data centers, offices, and apartment buildings for data or voice communications using various kinds of cable, most commonly category 5e (CAT-5e), category 6 (CAT-6), and fibre optic cabling and modular connectors. These standards define how to lay the cabling in various topologies in order to meet the needs of the customer, typically using a central patch panel (which is normally 19 inch rack-mounted), from where each modular connection can be used as needed. Each outlet is then patched into a network switch (normally also rack-mounted) for network use or into an IP or PBX (private branch exchange) telephone system patch panel.

Lines patched as data ports into a network switch require simple straight-through patch cables at each end to connect a computer. Voice patches to PBXs in most countries require an adapter at the remote end to translate the configuration on 8P8C modular connectors into the local standard telephone wall socket. No adapter is needed in the U.S. as the 6P2C and 6P4C plugs most commomly used with RJ11 and RJ14 telephone connections are physically and electrically compatible with the larger 8P8C socket. RJ25 and RJ61 connections are physically but not electrically compatible, and cannot be used. In the UK, an adapter must be present at the remote end as the 6-pin BT socket is physically incompatible with 8P8C.